sigamp - measure signal amplitudes of a WFDB record
sigamp -r
record [ options ... ]
sigamp measures either baseline-corrected
RMS amplitudes or (for suitably annotated ECG signals) normal QRS peak-to-peak
amplitudes for all signals of the specified record. It makes up to 300
measurements (but see -n below) for each signal and calculates trimmed means
(by discarding the largest and smallest 5% of the measurements and taking
the mean of the remaining 90%).
Options include:
- -a annotator
- Measure QRS
peak-to-peak amplitudes based on normal QRS annotations from the specified
annotator.
- -d dt1 dt2
- Set the measurement window relative to QRS annotations.
Defaults: dt1 = 0.05 (seconds before the annotation); dt2 = 0.05 (seconds
after the annotation).
- -f time
- Begin at the specified time in record (default:
the beginning of record).
- -h
- Print a usage summary.
- -H
- Read the signal files
in high-resolution mode (default: standard mode). These modes are identical
for ordinary records. For multifrequency records, the standard decimation
of oversampled signals to the frame rate is suppressed in high-resolution
mode (rather, all other signals are resampled at the highest sampling frequency).
- -n nmax
- Make up to nmax measurements on each signal (default: 300).
- -p
- Print
results in physical units (default: ADC units). -p may be followed by a single
character to specifify a time format (used with -q and -v when printing individual
measurements); choices are -pd (time of day and date if known), -pe (elapsed
time in hours, minutes, and seconds), -ph (elapsed time in hours), -pm (elapsed
time in minutes), -ps (elapsed time in seconds (default)), -pS (elapsed time
in sample intervals).
- -q
- Quick mode: print individual measurements only.
- -t
time
- Process until the specified time in record (default: the end of the
record). Processing will be terminated prematurely if 250 measurements
are made before reaching the specified time.
- -v
- Verbose mode: print individual
measurements as well as trimmed means.
- -w dtw
- Set RMS amplitude measurement
window. Default: dtw = 1 (second).
It may be necessary to set
and export the shell variable WFDB (see setwfdb(1)
).
calsig(1)
,
setwfdb(1)
, sigavg(1)
George B. Moody (george@mit.edu)
http://www.physionet.org/physiotools/wfdb/app/sigamp.c
Table of Contents
Up: WFDB Applications Guide
Please e-mail your comments and suggestions to webmaster@physionet.org, or post them to:
PhysioNet
MIT Room E25-505A
77 Massachusetts Avenue
Cambridge, MA 02139 USA
Updated 8 March 2019